{"id":2332,"date":"2026-10-02T00:29:37","date_gmt":"2026-10-02T00:29:37","guid":{"rendered":"https:\/\/www.bkl.nl\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/"},"modified":"2026-10-02T00:29:37","modified_gmt":"2026-10-02T00:29:37","slug":"how-to-specify-a-single-point-lifting-beam-for-controlled-loads","status":"publish","type":"post","link":"https:\/\/www.bkl.nl\/de\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/","title":{"rendered":"How to specify a single point lifting beam for controlled loads"},"content":{"rendered":"<p>A single point lifting beam can connect one crane hook to several load attachments, but rated capacity alone does not establish a controlled lift. The specification must also define how the load stays balanced, what movement is acceptable and how operators connect, position and release it without entering hazardous areas.<\/p>\n<p>For OEMs and high-tech manufacturers, this means treating the beam as part of a complete lifting arrangement. The load, crane, rigging, attachment interfaces and operating environment all influence performance. A useful specification gives engineering, safety, operations and procurement teams a common basis for selecting equipment and accepting the finished solution.<\/p>\n<h2 id=\"understand-the-suspension-arrangement\">Understand the suspension arrangement<\/h2>\n<p>In this article, \u201csingle point\u201d means <strong>one upper suspension point connecting the beam to the hoist<\/strong>. It does not mean that the load has only one attachment. The beam may distribute the load through two or more lower connections.<\/p>\n<p>A conventional lifting beam carries significant bending loads. A conventional spreader beam primarily carries compression through an arrangement with upper slings. The distinction matters because the load path, headroom and verification requirements differ.<\/p>\n<p>One suspension point also does not automatically prevent rotation around the vertical axis. A freely suspended assembly can turn even when it is balanced. Similarly, keeping a component approximately level does not establish accurate positioning during installation.<\/p>\n<p>Specify a single point lifting beam against defined control requirements: allowable tilt, acceptable rotation, positioning accuracy and clearance from surrounding equipment. If the task requires restraint or precise alignment, identify how the complete handling system will provide it.<\/p>\n<h2 id=\"specify-load-cases-not-just-maximum-mass\">Specify load cases, not just maximum mass<\/h2>\n<p>Start with the actual lifting task, including the conditions encountered during pickup, transport and placement. A component may have different mass and balance characteristics before and after accessories, transport frames or service modules are installed.<\/p>\n<p>The load definition should include:<\/p>\n<ul>\n<li><strong>Mass range:<\/strong> Minimum and maximum payload mass, including attached items lifted with the component.<\/li>\n<li><strong>Center-of-gravity envelope:<\/strong> Expected positions and uncertainty across all approved configurations.<\/li>\n<li><strong>Attachment data:<\/strong> Locations, permitted loading directions and verified capacities of the load\u2019s lifting interfaces.<\/li>\n<li><strong>Operating sequence:<\/strong> Pickup orientation, travel path, placement position and connection or release steps.<\/li>\n<li><strong>Service conditions:<\/strong> Lift frequency, expected service life and relevant temperature, cleanliness or corrosion constraints.<\/li>\n<\/ul>\n<p>Keep payload capacity separate from the load imposed on the crane. The hoist carries the payload plus the beam and associated rigging, subject to the applicable crane configuration and operating limits.<\/p>\n<p>For a single point lifting beam, each approved load case should identify the corresponding suspension position, lower attachment arrangement and operating restrictions. \u201cSuitable for all machine variants\u201d is not an adequate requirement unless those variants and their limits are defined.<\/p>\n<h3 id=\"check-load-sharing-rather-than-assuming-equal-reactions\">Check load sharing rather than assuming equal reactions<\/h3>\n<p>Two lower connections do not necessarily carry half the load each. Their reactions depend on the center of gravity and attachment geometry.<\/p>\n<p>For a simplified static case with vertical lower forces, two attachment points separated by distance <code>L<\/code> and a payload weight <code>W<\/code> acting at distance <code>x<\/code> from the left attachment:<\/p>\n<p><code>Left reaction = W \u00d7 (L \u2212 x) \/ L<\/code><\/p>\n<p><code>Right reaction = W \u00d7 x \/ L<\/code><\/p>\n<p>For example, a 1,000 kg payload with attachments 2 m apart and its center of gravity 1.2 m from the left attachment produces approximately 3.92 kN at the left connection and 5.89 kN at the right connection. This example excludes beam weight, rigging weight, dynamic effects and other design allowances. It illustrates unequal sharing, not a basis for selecting rated capacities.<\/p>\n<p>The single point lifting beam must be verified for the resulting attachment forces and structural load effects, not merely the combined payload mass. Inclined slings, offset brackets or non-coplanar connections require a more complete analysis.<\/p>\n<p>Balance also depends on the combined suspended assembly. The designer should assess the relationship between the upper suspension point and the combined center of gravity, including stability against unintended tilt.<\/p>\n<h2 id=\"define-interfaces-and-the-available-lifting-envelope\">Define interfaces and the available lifting envelope<\/h2>\n<p>A lifting tool can have sufficient structural capacity yet still be unsuitable because it cannot connect correctly or fit within the available space.<\/p>\n<p>Document the crane hook dimensions, upper connection geometry, shackle compatibility and required articulation. Connections should seat correctly without unintended side loading or interference. At the lower interfaces, define hole sizes, pin dimensions, engagement requirements and permitted force directions.<\/p>\n<p>For a single point lifting beam, include a dimensional drawing of the complete suspended arrangement rather than only the beam itself. Show the hook, connecting hardware, beam, lower rigging and payload in the relevant lifting positions.<\/p>\n<p>Headroom is the vertical space needed for that whole arrangement, including the travel required to clear supports and reach the installation position. Check it against the actual hook height and surrounding obstructions.<\/p>\n<p>Also verify whether operators can fit and remove connections without reaching beneath the suspended load. A connection that is accessible on a drawing may become inaccessible beside a machine enclosure or inside an assembly station.<\/p>\n<h3 id=\"document-the-receiving-environment\">Document the receiving environment<\/h3>\n<p>The installation route belongs in the specification, including doorways, floor capacity, turning space and the availability of suitable lifting infrastructure. Cleanroom applications may additionally require defined materials, finishes, lubricants and cleaning procedures compatible with the site\u2019s contamination controls.<\/p>\n<p>For medical-equipment OEMs supplying patient-facing settings, a dental practice such as <a href=\"https:\/\/thedentalloungerobina.com.au\/\">The Dental Lounge Robina<\/a> illustrates a different receiving environment from a production floor. For any installation in that type of setting, confirm access, floor protection and separation from clinical activity with the receiving site rather than assuming factory handling arrangements are available.<\/p>\n<p>The operating environment can determine whether a single point lifting beam is practical, even when the load and structural capacity are otherwise suitable.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.bkl.nl\/wp-content\/uploads\/single-point-lifting-beam-showing-the-upper-suspen-1790900964925-scaled.webp\" alt=\"Single point lifting beam showing the upper suspension connection, lower load interfaces and clearance above an industrial module\" class=\"blogseo-image\"><\/p>\n<h2 id=\"specify-restraint-usability-and-repeatability\">Specify restraint, usability and repeatability<\/h2>\n<p>Translate \u201ccontrolled handling\u201d into observable requirements. Depending on the application, these may include a maximum tilt during pickup, a defined orientation during travel or a permitted movement envelope near sensitive surfaces.<\/p>\n<p>Do not assume that shifting the suspension point resolves every control issue. It can improve balance, but it does not necessarily control yaw, oscillation or final alignment. Where these movements matter, assess an engineered guide, restraint system or approved handling method compatible with the lifting operation.<\/p>\n<p>Operator interaction should be part of the design review. Consider connection visibility, access to locking features, handling forces and the risk of trapping fingers during engagement. Operators should not have to stabilize a load by placing their hands between it and surrounding equipment.<\/p>\n<p>An adjustable single point lifting beam needs clearly identifiable settings and a verified means of securing each adjustment. Define how operators select the correct configuration and check engagement before lifting.<\/p>\n<p>For repetitive tasks, a dedicated interface or fixed setting may reduce setup steps and configuration errors. The objective is repeatable operation with clear limits, not flexibility that depends on undocumented operator judgment.<\/p>\n<h2 id=\"choose-standard-equipment-or-a-justified-custom-design\">Choose standard equipment or a justified custom design<\/h2>\n<p>A standard beam may be sufficient when its approved capacity, geometry, interfaces and instructions cover the complete task. Confirm compatibility with the actual load cases rather than relying on a catalog photograph or nominal lifting capacity.<\/p>\n<p>Custom engineering becomes more relevant when the load has an offset center of gravity, restricted attachment locations, sensitive surfaces or limited headroom. It may also be justified when connection work creates unnecessary physical strain or a standard arrangement requires repeated manual adjustments.<\/p>\n<p>A single point lifting beam should not be custom-made simply because the payload is valuable. The decision should follow from a documented mismatch between available equipment and the required operating conditions. BKL\u2019s explanation of <a href=\"https:\/\/www.bkl.nl\/de\/blog\/how-custom-lifting-beams-improve-control-for-complex-loads\/\">how custom lifting beams improve control for complex loads<\/a> provides further context for evaluating those constraints.<\/p>\n<p>Compare lifecycle costs as well as purchase price. Include setup time, inspection access, replacement parts, storage, maintenance and the consequences of tooling being unavailable. A simpler standard solution can be the better choice when it meets the requirements without workarounds.<\/p>\n<h2 id=\"turn-the-specification-into-acceptance-criteria\">Turn the specification into acceptance criteria<\/h2>\n<p>A procurement document should state both the requirement and how compliance will be demonstrated. This prevents disagreements about whether calculations, testing or an operational demonstration are needed.<\/p>\n<p>Use a requirements matrix such as the following when specifying a single point lifting beam. The verification method and acceptance limits must be agreed for the particular application.<\/p>\n<div class=\"blogseo-table-wrapper\">\n<table class=\"blogseo-table\">\n<thead>\n<tr>\n<th>Specification area<\/th>\n<th>Requirement to define<\/th>\n<th>Evidence to request<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Load cases<\/td>\n<td>Payload range, center-of-gravity envelope and approved configurations<\/td>\n<td>Load-case schedule and design calculations<\/td>\n<\/tr>\n<tr>\n<td>Structural capacity<\/td>\n<td>Working load limit and configuration-dependent restrictions<\/td>\n<td>Verification covering relevant structural and connection failure modes<\/td>\n<\/tr>\n<tr>\n<td>Interfaces<\/td>\n<td>Dimensions, tolerances, engagement and permitted force directions<\/td>\n<td>Approved drawings and interface checks<\/td>\n<\/tr>\n<tr>\n<td>Handling control<\/td>\n<td>Allowable tilt, rotation and positioning movement<\/td>\n<td>Engineering assessment and agreed functional demonstration<\/td>\n<\/tr>\n<tr>\n<td>Operating envelope<\/td>\n<td>Headroom, travel clearance and connection access<\/td>\n<td>Layout review and representative fit checks<\/td>\n<\/tr>\n<tr>\n<td>Lifecycle support<\/td>\n<td>Inspection access, maintenance needs and replacement criteria<\/td>\n<td>Instructions, inspection guidance and parts information<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Avoid acceptance statements such as \u201ceasy to use\u201d without supporting criteria. Instead, define the connection sequence, operator access requirements and how the correct setup will be confirmed.<\/p>\n<p>Where representative trials are appropriate, agree the load configuration, test environment, observers and pass\/fail criteria beforehand. A successful lift in one configuration does not demonstrate suitability for every configuration in the specification.<\/p>\n<h3 id=\"clarify-conformity-assessment-and-test-scope\">Clarify conformity assessment and test scope<\/h3>\n<p>For equipment placed on the EU market, establish the applicable product classification and conformity obligations early. A separately supplied lifting beam will commonly fall within the lifting-accessory framework, but responsibility and scope should be confirmed for the actual supply arrangement.<\/p>\n<p>As of October 2026, the Machinery Directive 2006\/42\/EC remains the principal framework for relevant machinery and lifting accessories. The <a href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2023\/1230\/oj\">EU Machinery Regulation (EU) 2023\/1230<\/a> generally applies from January 20, 2027. Plan according to the applicable placing-on-the-market date and transitional provisions.<\/p>\n<p>EN 13155, concerning non-fixed load lifting attachments, may be relevant to the design. Confirm the applicable edition, scope and harmonized status rather than treating a standard reference as automatic proof of conformity.<\/p>\n<p>The acceptance package for a single point lifting beam should identify the applicable documentation, marking, instructions and conformity declaration requirements. Agree the scope of any proof or overload testing separately. Test loads and procedures must follow the applicable requirements and engineering plan, not a universal multiplier selected without context.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.bkl.nl\/wp-content\/uploads\/engineering-review-of-lifting-beam-drawings-interf-1790900966196-scaled.webp\" alt=\"Engineering review of lifting beam drawings, interface dimensions and an acceptance requirements matrix\" class=\"blogseo-image\"><\/p>\n<h2 id=\"plan-inspection-and-support-before-delivery\">Plan inspection and support before delivery<\/h2>\n<p>Specify who will own the equipment, maintain its records and authorize its use. A beam shared between departments needs configuration control just as much as a dedicated production tool.<\/p>\n<p>Inspection planning for a single point lifting beam should account for duty, environment, wear mechanisms and the applicable legal and manufacturer requirements. Do not assume that one annual interval suits every application or that visible condition alone establishes fitness for use.<\/p>\n<p>Instructions should distinguish pre-use checks from periodic examinations and maintenance. They should also define when equipment must be withdrawn, for example after an overload event, significant impact, unexplained deformation or damage to a load-bearing connection.<\/p>\n<p>BKL\u2019s guide to <a href=\"https:\/\/www.bkl.nl\/de\/blog\/what-inspection-and-certification-of-lifting-equipment-involves\/\">inspection and certification of lifting equipment<\/a> explains why examination, load testing and certification need clearly defined scopes.<\/p>\n<p>Include access to critical welds, pins, bushes and locking mechanisms in the original design review. Agree how repairs, replacement components and proposed modifications will be assessed. Changes to attachment positions or rated configurations require technical review rather than an informal workshop adjustment.<\/p>\n<h2 id=\"faqs-about-specifying-a-single-point-lifting-beam\">FAQ&#039;s about specifying a single point lifting beam:<\/h2>\n<p><strong>Does one upper suspension point mean the load has one lifting point?<\/strong> No. One upper point connects the beam to the hoist, while several lower interfaces may connect it to the payload. Specify both arrangements explicitly.<\/p>\n<p><strong>Will a balanced beam prevent the load from rotating?<\/strong> Not necessarily. Balance addresses tilt associated with the center of gravity. Rotation around the vertical suspension axis may require a separate restraint or handling method.<\/p>\n<p><strong>Can the same beam lift several machine variants?<\/strong> Yes, if every variant falls within verified load cases, interface limits and approved configurations. Similar dimensions do not establish equivalent lifting behavior.<\/p>\n<p><strong>Is a load test enough to accept the beam?<\/strong> No. A test does not replace design verification, interface checks, risk assessment or the required documentation. Its purpose and coverage should be defined in the acceptance plan.<\/p>\n<h2 id=\"discuss-the-lifting-task-with-bkl\">Discuss the lifting task with BKL<\/h2>\n<p>Before requesting a quotation for a single point lifting beam, assemble the payload drawings, mass and center-of-gravity data, lifting-interface details, site layout and intended operating sequence. Highlight unknowns rather than filling them with optimistic assumptions.<\/p>\n<p>BKL can support individual stages or a complete scope covering engineering, production, assembly, installation, inspection and maintenance. The discussion may lead to a standard solution, an improvement to existing tooling or a custom design, depending on the application.<\/p>\n<p>Contact BKL by phone or email through <a href=\"https:\/\/www.bkl.nl\/de\/\">BKL\u2019s website<\/a> to schedule an application review. Ask for a quotation with a defined technical scope, acceptance evidence and lifecycle support requirements so the proposal can be assessed by engineering, safety and operations as well as procurement.<\/p>","protected":false},"excerpt":{"rendered":"<p>A single point lifting beam can connect one crane hook to several load attachments, but rated capacity alone does not establish a controlled lift. The specification must also define how the load stays<\/p>","protected":false},"author":8,"featured_media":2329,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[17],"class_list":["post-2332","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-knowledge-base"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to specify a single point lifting beam for controlled loads<\/title>\n<meta name=\"description\" content=\"Specify a single point lifting beam with clear load cases, balance checks and acceptance criteria for safer, controlled industrial lifts.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.bkl.nl\/de\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to specify a single point lifting beam for controlled loads\" \/>\n<meta property=\"og:description\" content=\"Specify a single point lifting beam with clear load cases, balance checks and acceptance criteria for safer, controlled industrial lifts.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.bkl.nl\/de\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/\" \/>\n<meta property=\"og:site_name\" content=\"BKL\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-02T00:29:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.bkl.nl\/wp-content\/uploads\/how-to-specify-a-single-point-lifting-beam-for-con-1790900963453-scaled.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1429\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Team BKL\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"How to specify a single point lifting beam for controlled loads\" \/>\n<meta name=\"twitter:description\" content=\"Specify a single point lifting beam with clear load cases, balance checks and acceptance criteria for safer, controlled industrial lifts.\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/www.bkl.nl\/wp-content\/uploads\/how-to-specify-a-single-point-lifting-beam-for-con-1790900963453-scaled.webp\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"Team BKL\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"10\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":[\"Article\",\"BlogPosting\"],\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/blog\\\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/blog\\\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\\\/\"},\"author\":{\"name\":\"Team BKL\",\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/#\\\/schema\\\/person\\\/06359a37f00168702d76a4352678bbba\"},\"headline\":\"How to specify a single point lifting beam for controlled loads\",\"datePublished\":\"2026-10-02T00:29:37+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/blog\\\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\\\/\"},\"wordCount\":2097,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/blog\\\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.bkl.nl\\\/wp-content\\\/uploads\\\/how-to-specify-a-single-point-lifting-beam-for-con-1790900963453-scaled.webp\",\"keywords\":[\"Knowledge Base\"],\"articleSection\":[\"Blog\"],\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.bkl.nl\\\/blog\\\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/blog\\\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\\\/\",\"url\":\"https:\\\/\\\/www.bkl.nl\\\/blog\\\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\\\/\",\"name\":\"How to specify a single point lifting beam for controlled loads\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/blog\\\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/blog\\\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.bkl.nl\\\/wp-content\\\/uploads\\\/how-to-specify-a-single-point-lifting-beam-for-con-1790900963453-scaled.webp\",\"datePublished\":\"2026-10-02T00:29:37+00:00\",\"description\":\"Specify a single point lifting beam with clear load cases, balance checks and acceptance criteria for safer, controlled industrial lifts.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/blog\\\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.bkl.nl\\\/blog\\\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/blog\\\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.bkl.nl\\\/wp-content\\\/uploads\\\/how-to-specify-a-single-point-lifting-beam-for-con-1790900963453-scaled.webp\",\"contentUrl\":\"https:\\\/\\\/www.bkl.nl\\\/wp-content\\\/uploads\\\/how-to-specify-a-single-point-lifting-beam-for-con-1790900963453-scaled.webp\",\"width\":2560,\"height\":1429,\"caption\":\"How to specify a single point lifting beam for controlled loads - Main Image\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/blog\\\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.bkl.nl\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to specify a single point lifting beam for controlled loads\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/#website\",\"url\":\"https:\\\/\\\/www.bkl.nl\\\/\",\"name\":\"BKL\",\"description\":\"Smart engineering\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.bkl.nl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/#organization\",\"name\":\"BKL Engineering\",\"url\":\"https:\\\/\\\/www.bkl.nl\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.bkl.nl\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/logo_bkl_on_light.svg\",\"contentUrl\":\"https:\\\/\\\/www.bkl.nl\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/logo_bkl_on_light.svg\",\"width\":\"1024\",\"height\":\"1024\",\"caption\":\"BKL Engineering\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/bkl-bv\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/#\\\/schema\\\/person\\\/06359a37f00168702d76a4352678bbba\",\"name\":\"Team BKL\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.bkl.nl\\\/wp-content\\\/litespeed\\\/avatar\\\/abf3f527148591071f9d56774e4683b5.jpg?ver=1795102918\",\"url\":\"https:\\\/\\\/www.bkl.nl\\\/wp-content\\\/litespeed\\\/avatar\\\/abf3f527148591071f9d56774e4683b5.jpg?ver=1795102918\",\"contentUrl\":\"https:\\\/\\\/www.bkl.nl\\\/wp-content\\\/litespeed\\\/avatar\\\/abf3f527148591071f9d56774e4683b5.jpg?ver=1795102918\",\"caption\":\"Team BKL\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to specify a single point lifting beam for controlled loads","description":"Specify a single point lifting beam with clear load cases, balance checks and acceptance criteria for safer, controlled industrial lifts.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.bkl.nl\/de\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/","og_locale":"de_DE","og_type":"article","og_title":"How to specify a single point lifting beam for controlled loads","og_description":"Specify a single point lifting beam with clear load cases, balance checks and acceptance criteria for safer, controlled industrial lifts.","og_url":"https:\/\/www.bkl.nl\/de\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/","og_site_name":"BKL","article_published_time":"2026-10-02T00:29:37+00:00","og_image":[{"width":2560,"height":1429,"url":"https:\/\/www.bkl.nl\/wp-content\/uploads\/how-to-specify-a-single-point-lifting-beam-for-con-1790900963453-scaled.webp","type":"image\/webp"}],"author":"Team BKL","twitter_card":"summary_large_image","twitter_title":"How to specify a single point lifting beam for controlled loads","twitter_description":"Specify a single point lifting beam with clear load cases, balance checks and acceptance criteria for safer, controlled industrial lifts.","twitter_image":"https:\/\/www.bkl.nl\/wp-content\/uploads\/how-to-specify-a-single-point-lifting-beam-for-con-1790900963453-scaled.webp","twitter_misc":{"Verfasst von":"Team BKL","Gesch\u00e4tzte Lesezeit":"10\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["Article","BlogPosting"],"@id":"https:\/\/www.bkl.nl\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/#article","isPartOf":{"@id":"https:\/\/www.bkl.nl\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/"},"author":{"name":"Team BKL","@id":"https:\/\/www.bkl.nl\/#\/schema\/person\/06359a37f00168702d76a4352678bbba"},"headline":"How to specify a single point lifting beam for controlled loads","datePublished":"2026-10-02T00:29:37+00:00","mainEntityOfPage":{"@id":"https:\/\/www.bkl.nl\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/"},"wordCount":2097,"commentCount":0,"publisher":{"@id":"https:\/\/www.bkl.nl\/#organization"},"image":{"@id":"https:\/\/www.bkl.nl\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/#primaryimage"},"thumbnailUrl":"https:\/\/www.bkl.nl\/wp-content\/uploads\/how-to-specify-a-single-point-lifting-beam-for-con-1790900963453-scaled.webp","keywords":["Knowledge Base"],"articleSection":["Blog"],"inLanguage":"de","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.bkl.nl\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.bkl.nl\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/","url":"https:\/\/www.bkl.nl\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/","name":"How to specify a single point lifting beam for controlled loads","isPartOf":{"@id":"https:\/\/www.bkl.nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.bkl.nl\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/#primaryimage"},"image":{"@id":"https:\/\/www.bkl.nl\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/#primaryimage"},"thumbnailUrl":"https:\/\/www.bkl.nl\/wp-content\/uploads\/how-to-specify-a-single-point-lifting-beam-for-con-1790900963453-scaled.webp","datePublished":"2026-10-02T00:29:37+00:00","description":"Specify a single point lifting beam with clear load cases, balance checks and acceptance criteria for safer, controlled industrial lifts.","breadcrumb":{"@id":"https:\/\/www.bkl.nl\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.bkl.nl\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.bkl.nl\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/#primaryimage","url":"https:\/\/www.bkl.nl\/wp-content\/uploads\/how-to-specify-a-single-point-lifting-beam-for-con-1790900963453-scaled.webp","contentUrl":"https:\/\/www.bkl.nl\/wp-content\/uploads\/how-to-specify-a-single-point-lifting-beam-for-con-1790900963453-scaled.webp","width":2560,"height":1429,"caption":"How to specify a single point lifting beam for controlled loads - Main Image"},{"@type":"BreadcrumbList","@id":"https:\/\/www.bkl.nl\/blog\/how-to-specify-a-single-point-lifting-beam-for-controlled-loads\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.bkl.nl\/"},{"@type":"ListItem","position":2,"name":"How to specify a single point lifting beam for controlled loads"}]},{"@type":"WebSite","@id":"https:\/\/www.bkl.nl\/#website","url":"https:\/\/www.bkl.nl\/","name":"BKL","description":"Intelligente Technik","publisher":{"@id":"https:\/\/www.bkl.nl\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.bkl.nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.bkl.nl\/#organization","name":"BKL Engineering","url":"https:\/\/www.bkl.nl\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.bkl.nl\/#\/schema\/logo\/image\/","url":"https:\/\/www.bkl.nl\/wp-content\/uploads\/2022\/03\/logo_bkl_on_light.svg","contentUrl":"https:\/\/www.bkl.nl\/wp-content\/uploads\/2022\/03\/logo_bkl_on_light.svg","width":"1024","height":"1024","caption":"BKL Engineering"},"image":{"@id":"https:\/\/www.bkl.nl\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/bkl-bv"]},{"@type":"Person","@id":"https:\/\/www.bkl.nl\/#\/schema\/person\/06359a37f00168702d76a4352678bbba","name":"Team BKL","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.bkl.nl\/wp-content\/litespeed\/avatar\/abf3f527148591071f9d56774e4683b5.jpg?ver=1795102918","url":"https:\/\/www.bkl.nl\/wp-content\/litespeed\/avatar\/abf3f527148591071f9d56774e4683b5.jpg?ver=1795102918","contentUrl":"https:\/\/www.bkl.nl\/wp-content\/litespeed\/avatar\/abf3f527148591071f9d56774e4683b5.jpg?ver=1795102918","caption":"Team BKL"}}]}},"_links":{"self":[{"href":"https:\/\/www.bkl.nl\/de\/wp-json\/wp\/v2\/posts\/2332","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bkl.nl\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bkl.nl\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bkl.nl\/de\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bkl.nl\/de\/wp-json\/wp\/v2\/comments?post=2332"}],"version-history":[{"count":0,"href":"https:\/\/www.bkl.nl\/de\/wp-json\/wp\/v2\/posts\/2332\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bkl.nl\/de\/wp-json\/wp\/v2\/media\/2329"}],"wp:attachment":[{"href":"https:\/\/www.bkl.nl\/de\/wp-json\/wp\/v2\/media?parent=2332"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bkl.nl\/de\/wp-json\/wp\/v2\/categories?post=2332"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bkl.nl\/de\/wp-json\/wp\/v2\/tags?post=2332"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}